Weak or Bypassable Physical Locks

Doors, cabinets or other physical barriers protecting sensitive areas use locks or fittings that can be opened quickly without the key or credential.

SeverityMedium
CVSS 3.16.8 CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Open in the calculator
CVSS 4.07 CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Open in the calculator
CWECWE-1263: Improper Physical Access Control
MITRE ATT&CKT1200 Hardware Additions
CategoryInsecure Design

Description

Locks and door hardware protecting sensitive areas or equipment could be opened or bypassed quickly without the key or access credential. Typical findings are latches that can be pushed back with a thin tool through the gap between door and frame (shimming or slipping); lever handles that can be operated from the other side of the door with a tool passed underneath it or through a letterbox; request-to-exit sensors that release a door when triggered from outside through a gap; push-bar exits that can be reached from outside; low-security cylinders and wafer locks that can be picked or bypassed in seconds; combination locks left at default codes; and network cabinets and server racks fitted with locks that share a widely available key.

Many of these weaknesses lie in how doors and fittings are installed rather than in the lock itself, and they bypass electronic access control entirely, leaving no record that the door was opened. An intruder can therefore enter server rooms, network equipment rooms, offices and storage areas, or open cabinets, without leaving signs of forced entry and often without triggering any alarm, gaining direct access to equipment, data and storage media and the opportunity to install covert network devices. The attacker must already be on site, often in a semi-public area, which limits the rating.

The finding is identified by inspecting doors, frames, locks and exit hardware on the routes to sensitive areas and, where agreed in scope, attempting non-destructive bypass techniques and recording how long each took.

Remediation

Assess the barriers on the route to each sensitive area as a whole, and strengthen the weakest point first:

  • Fit latch guards or anti-shim plates, and use deadlocking latches that cannot be pushed back once the door is closed.
  • Close gaps under and around doors with thresholds, door sweeps and seals, and protect inside lever handles where under-door tools could reach them.
  • Position and adjust request-to-exit sensors so that they cannot be triggered from outside, and protect push-bar exits from being reached through gaps.
  • Replace low-security cylinders and locks on sensitive doors and cabinets with products tested to a recognised security standard, using guidance such as that from the UK National Protective Security Authority (NPSA), with a restricted key system and a key register.
  • Change default combinations, and replace common keys on network cabinets and racks with unique or electronically controlled locks.
  • Fit door contacts and alarms to sensitive doors, so that opening without a valid access event is detected.

Confirm improvement by repeating the bypass attempts after the changes.

References


Add This Finding to Your Library

In Pental this write-up is in Settings, Library. Add to my library copies it into your own, rated in your firm's CVSS version, ready to put in your own words.

Free trial  ·  No card required

Only need the reporting? Our reporting tool is free and open source, with the same library.